Pressure Switch - PPS1 Series | Série de produits

Filtrer par

    Aucun filtre slectionn

Créez votre compte Parker aujourd'hui !

Créez un compte pour gérer tout ce que vous faites avec Parker, de vos préférences shopping à votre accès aux applications.


LOADING IMAGES
Pressure Switch - PPS1 Series

Pressure Switch - PPS1 Series

The PPS1 pressure switch monitors the air pressure in your pneumatic system. When the pressure in your system either drops below or exceeds the set point ressure, an electrical output is given.

Caractéristiques techniques

  • Niveau d'étanchéité : IP66, NEMA 4, IP54, NEMA 13
  • Température de service : -40 to 220 °F, -40 to 105 °C
  • Pression de service maximale : 250 psig : Ranges 1, 2, 3, 2000 psig : Range 4, 17.2 bar : Ranges 1, 2, 3, 137.9 bar : Range 4
  • Courant de sortie nominal : 3 A @ 125 VAC, 2 A @ 30 VDC (Resistive)
  • Durée de vie utile : 1 Million Cycles
  • Mécanisme de réglage : Anodized Aluminum Knob
  • Matériau du corps : Brass
  • Matériau du joint : Nitrile Butadiene Rubber (NBR)
Safety Warning

Description complète du produit

The PPS1 pressure switch monitors the air pressure in your pneumatic system. When the pressure in your system either drops below or exceeds the set point pressure, an electrical output is given. Repeatability — accuracy is the maximum allowable set point deviation of a single pressure or temperature switch under one given set of environmental and operational conditions.

Single Pole Double Throw (SPDT) Switching element — A SPDT switching element has one normally open, one normally closed and one common terminal. Three terminals mean that the switch can be wired with the circuit either normally open (NO), or normally closed (NC), or both.

Dead Band — The dead band, sometimes referred to as “differential” or “hysterisis”, is the change in pressure between actuation and deactuation set points.

Markets
• General Industrial
• Automotive
• Factory Automation

Features/Benefits
• Single Pole Double Throw (SPDT) Switching element — A SPDT switching element has one normally open, one normally closed and one common terminal. Three terminals mean that the switch can be wired with the circuit either normally open (NO), or normally closed (NC), or both.
• Dead Band — The dead band, sometimes referred to as “differential” or “hysterisis”, is the change in pressure between actuation and deactuation set points.

Applications
• General Industrial
• Conveyance
• Packaging
• Assembly

Documents annexes

×
Produits

687541
687577