LQC, Liquid Cooling CDU Quick Disconnects - CDT Series LQC, Liquid Cooling CDU Quick Disconnects - CDT Series

LQC, Liquid Cooling CDU Quick Disconnects - CDT Series

Parker’s CDT Series, flat face, threaded quick disconnects, are optimized for CDU and pump, liquid cooling applications in data centers, servers and supercomputers. Large Quick Connect, LQC V2 spec is based on an Open Compute, OCP design.

Technické parametry

  • Aplikace: Liquid Cooling, Thermal Management
  • Maximální pracovní tlak: 12 bar, 175 psi
  • Typ produktu: Screw to Connect
  • Maximální provozní teplota: 60 °C, 140 °F
  • Typ ventilu: Flat Face
  • Minimální provozní teplota: 32 °F
  • Velikost tělesa: 1" inch
  • Maximální průtok: 26 gal/min
  • Typ připojení: Female BSPP
  • Materiál tělesa: Stainless Steel
  • Těsnicí materiál: EPDM
  • Technické parametry: OCP, LQC V2
Safety Warning

Celý popis produktu

CDT Series quick disconnect couplings, developed in collaboration with OCP is a critical component within the data center liquid cooling architecture. Both plugs and sockets are interoperable and interchangeable with other OCP-approved LQC manufacturers. Parker's CDT is compliant with V2 performance and testing specification requirements. The threaded design provides mechanical advantage for connecting under pressure, while the flat face valving automatically shuts to prevent spillage.

These QDs are manufactured with high-quality stainless steel and are available in a wide range of port configurations to be deployed across several designs of rack manifolds, flexible hoses, and IT gears.

Parker’s CDT series products are assembled and tested in a clean room environment to reduce contamination, with final assemblies tested to a helium-leak specification to ensure robust assembly and trusted quality.

Technical Characteristics:
- Sizes: 1”
- Materials: Stainless Steel
- Port Ends: Male ORB
- Seal Material: EPDM
- V2 Compliant

Markets & Applications:
- Information Technology
- Electronics
- Data Centers
- Supercomputers
- Liquid Cooling
- Servers
- Rackable Server Systems

Features/Benefits:
- Flush-face valve design prevents fluid loss and optimum protection of electrical components
- Threaded design provides mechanical advantage for connect under pressure capabilities
- End of line helium leak testing for quality assurance
- Reduced pressure drop for superior energy efficiency and system performance
- Manufacturing and assembly processes that reduces contamination
- Red and Blue color coding bands provided