OBSOLETE: CL-Constant Wattage Temptrace™ for Low Temperature Maintenance | Product Series

Filter by

    No filters selected

Number of Tubes

Tubing Material

Tube Size (inch)

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.


LOADING IMAGES
OBSOLETE: CL-Constant Wattage Temptrace™ for Low Temperature Maintenance

OBSOLETE: CL-Constant Wattage Temptrace™ for Low Temperature Maintenance OBSOLETE

Note: This product is no longer available - please contact us for further assistance.

Technical Specifications

  • Heat Output: 4 to 18 W/ft
  • Maximum Operating Temperature: 121 °C, 250 °F, 400 °F (when power to heating cable is off), 204 °C (when power to heating cable is off)
  • Number of Tubes: 1 to Multiple
  • Cover Material: Flame Resistant - PVC, TPE, PE & PU, PU, TPR, LDPE, PVDF
  • Heating Cable Voltage: 120 to 240 VAC
  • Specifications Met: General Purpose & FM Class I, Division 2 Areas
  • Tube Material: Seamless Copper Type 122 DHP ASTM B68/B75, Welded and Seamless Stainless Steel Type 316/316L ASTM A269, Polytetrafluoroethylene (PTFE), Perfluoroalkoxy Alkanes (PFA), Fluorinated Ethylene Propylene (FEP) (Other Materials available Upon Request)
  • Tube Outside Diameter: 1/8 to 1 inch (metric sizes also available from 2mm to 16mm)
  • Cover Color: Black (Other colors available upon request. See How to Specify & Order for Details.)
Safety Warning

Full Product Description

This product is no longer available from Parker. Contact us to find an alternative solution for your application.

Parflex CL Constant Wattage Temptrace™ electric trace tubing is capable of maintaining temperatures up to 250°F (121°C) and withstanding a maximum internal exposure up to 400°F (204°C) to effectively provide freeze protection, viscosity maintenance and low process temperature maintenance in applications that involve analyzer, impulse, and instrument lines, small diameter process lines, stack gas sampling lines and utility lines. The electric trace tubing consists of a process tube traced with a constant wattage heating cable, a heat transfer aluminum foil wrap for even heat distribution for precise temperature control, a non-hygroscopic glass fiber insulation for minimum heat loss, and a black, 105°C-rated, flame-resistant PVC (FR-PVC) jacket. This protective jacket safeguards the tubing against corrosive atmospheres, water, oils, acids, alkalies and most chemicals. For more information regarding tolerable temperature ranges and order details for CL Constant Wattage Temptrace™ tubing, refer to our latest literature on the Product Support tab.

Markets:  
• Process Control & Analyzer Systems

Features/Benefits:
• Designed to withstand a variety of temperature ranges
• Aluminum heat transfer foil allows for even heat distribution for precise temperature control
• Air-spaced, cross wrapped applied non-hygroscopic fiberglass thermal insulation provides minimum heat loss
• Standard black, flame-resistant PVC (FR-PVC) jacket protects the tubing against corrosive atmospheres, water, oils, acids, alkalies and most chemicals
• Product series is highly customizable - multiple options are available for tubing materials, tubing sizes, wall thicknesses, heating cable voltage and heat output, cover material and color

Applications:
• Provides freeze protection and viscosity maintenance
• Analyzer, impulse and instrument lines
• Small diameter process lines
• Stack gas sampling lines
• Utility lines

Technical Specifications:
• Standard Tubing Materials: Type 122 DHP Seamless Copper, 316/316L Welded and Seamless Stainless Steel, PFA, FEP and PTFE
• Insulation: Non-hygroscopic fiberglass
• Cover: FR-PVC
• Additional jacket materials and wall thicknesses are available upon request
• Each tube in every length of Parflex Temptrace™ is pressure tested prior to shipment to assure the instrument engineer a high-quality, reliable, trouble-free product
• Standard product has a Maximum Temperature Rating (MTR) of 400°F (204.4°C) when power to the heating cable is off, and 250°F (121.1°C) when power to the heating cable is on
        o Maximum Temperature Rating is the maximum allowable temperature of the tracing fluid; temperatures in excess of this may damage the product or alter its performance
• Accessories are available for electrical connections, bundle splicing and end terminations

NOTE: It is absolutely necessary to seal the ends against contamination from moisture and/or corrosive liquids. Parker Hannifin cannot assume any liability for product damage caused by moisture from unsealed ends.
Products Number of Tubes Tubing Material Tube Size (inch)
CL-412-10435A 1 Seamless Copper Type 122 DHP ASTM B68/B75 1/4
CL-412-20435A 1 Welded Stainless Steel Typer 316/316L ASTM A269 1/4
CL-412-B0435A 1 Seamless Stainless Steel Type 316/316L ASTM A269 1/4
CL-412-T0435A 1 TFE Flouropolymer 1/4
CL-412-P0435A 1 PFA Flouropolymer 1/4
CL-412-F0435A 1 FEP Flouropolymer 1/4
CL-412-10435B 2 Seamless Copper Type 122 DHP ASTM B68/B75 1/4
CL-412-20435B 2 Welded Stainless Steel Typer 316/316L ASTM A269 1/4
CL-412-B0435B 2 Seamless Stainless Steel Type 316/316L ASTM A269 1/4
CL-412-T0435B 2 TFE Flouropolymer 1/4
CL-412-P0435B 2 PFA Flouropolymer 1/4
CL-412-F0435B 2 FEP Flouropolymer 1/4
CL-412-10635A 1 Seamless Copper Type 122 DHP ASTM B68/B75 3/8
CL-412-20635A 1 Welded Stainless Steel Typer 316/316L ASTM A269 3/8
CL-412-B0635A 1 Seamless Stainless Steel Type 316/316L ASTM A269 3/8
CL-412-T0635A 1 TFE Flouropolymer 3/8
CL-412-P0635A 1 PFA Flouropolymer 3/8
CL-412-F0635A 1 FEP Flouropolymer 3/8
CL-412-10635B 2 Seamless Copper Type 122 DHP ASTM B68/B75 3/8
CL-412-20635B 2 Welded Stainless Steel Typer 316/316L ASTM A269 3/8
CL-412-B0635B 2 Seamless Stainless Steel Type 316/316L ASTM A269 3/8
CL-412-T0635B 2 TFE Flouropolymer 3/8
CL-412-P0635B 2 PFA Flouropolymer 3/8
CL-412-F0635B 2 FEP Flouropolymer 3/8
CL-412-10835A 1 Seamless Copper Type 122 DHP ASTM B68/B75 1/2
CL-412-20835A 1 Welded Stainless Steel Typer 316/316L ASTM A269 1/2
CL-412-B0835A 1 Seamless Stainless Steel Type 316/316L ASTM A269 1/2
CL-412-T0835A 1 TFE Flouropolymer 1/2
CL-412-P0835A 1 PFA Flouropolymer 1/2
CL-412-F0835A 1 FEP Flouropolymer 1/2
CL-412-10835B 2 Seamless Copper Type 122 DHP ASTM B68/B75 1/2
CL-412-20835B 2 Welded Stainless Steel Typer 316/316L ASTM A269 1/2
CL-412-B0835B 2 Seamless Stainless Steel Type 316/316L ASTM A269 1/2
CL-412-T0835B 2 TFE Flouropolymer 1/2
CL-412-P0835B 2 PFA Flouropolymer 1/2
CL-412-F0835B 2 FEP Flouropolymer 1/2

687PDC
687563