OBSOLETE: Self-Regulating High Temperature Maintenance Bundles - SH-Temptrace™ | Parker NA

OBSOLETE: Self-Regulating High Temperature Maintenance Bundles - SH-Temptrace™ | Product Series

Filter by

    No filters selected

Number of Tubes

Tubing Material

Tube O.D. (inch)

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.

OBSOLETE: Self-Regulating High Temperature Maintenance Bundles - SH-Temptrace™

OBSOLETE: Self-Regulating High Temperature Maintenance Bundles - SH-Temptrace™ OBSOLETE

Note: This product is no longer available - please contact us for further assistance.

Technical Specifications

  • Number of Tubes: 1 to Multiple
  • Cover Material: Flame Resistant - PVC, TPE, PE & PU, PU, TPR, LDPE, PVDF
  • Maximum Operating Temperature: 204 °C, 400 °F
  • Tube Material: Seamless Stainless Steel Type 316/316L ASTM A269 (Other materials available upon request. See How to Specify and Order for details), Welded Stainless Steel Type 316/316L ASTM A269 (Other materials available upon request. See How to Specify and Order for details), Seamless Copper Type 122 DHP ASTM B68/B75 (Other materials available upon request. See How to Specify and Order for details)
  • Tube Outside Diameter: 1/8 to 1 inch (metric sizes also available from 2mm to 16mm)
  • Nominal Outside Diameter: 1.21 to 1.99 inch
  • Minimum Bend Radius: 7 to 12 inch
  • Maximum Internal Temperature: 400 °F, 204 °C
  • Heat Output: 3 to 20 W/ft
  • Input Voltage: 120 VAC, 240 VAC
  • Circuit Length: 285 to 360 ft
  • Circuit Breaker Contact Rating: 30 A
  • Cover Color: Black (Other colors available upon request. See How to Specify & Order for Details.)
Safety Warning

Full Product Description

Self-Regulating High Temperature (SH) Temptrace™ is designed to provide temperature maintenance for gases, liquids and other process materials in operating environments with harsh conditions. SH-Temptrace consists of one or multiple insulated and heated tubes with a self-regulating cable for freeze protection and high temperature maintenance applications. With customization options available for numerous application requirements and a thermal insulation that allows for the transfer of fluids or gases up to 400°F (204°C), it is the optimal solution for applications in which high temperatures must be maintained throughout the conveyance process of liquids and gases. Review the literature provided in the Product Support tab for additional information regarding this product.

Markets:
• Chemical Processing and Refineries

Features:
• Highly customizable to fulfill various application requirements, with multiple options available for tubing materials, tubing sizes, wall thickness, heating cable voltage and heat output, cover material and color
• Designed with a Fluoropolymer jacket over the heating cable to provide additional protection against many harsh environments
• Maintains an outer jacket surface temperature of 140°F (60°C) or less, meeting NEC Personnel Protection Code 427.12
• Able to maintain process tube temperatures of 250°F (121.1°C), depending on ambient conditions
• Process tubes can be steam cleaned at temperatures up to 400°F (204°C) when power to the heating cable is off

Applications:
• High temperature liquids, gases and other process materials

NOTE: It is absolutely necessary to seal the ends against contamination from moisture and/or corrosive liquids. Parker Hannifin cannot assume any liability for product damage caused by moisture from unsealed ends.

Related Documents

×

687PDC
687563