Get your Parker account Today!
Create one account to manage everything you do with Parker, from your shopping preferences to your application access.
Create one account to manage everything you do with Parker, from your shopping preferences to your application access.
UL 429A certified solenoid valves are required for use as pre-action pilot valves in various fire suppression deluge systems.
| Literature and Reference Materials |
|---|
| Tube Seal |
| Products | Valve Type | Function | Port Size | Port Type | Actuation Type | Minimum Pressure Differential | Maximum Pressure Differential | Body Material | Seal Material | Maximum Fluid Temperature | Maximum Ambient Temperature | Orifice Size | Main Flow Coefficient | Input Voltage | Power Consumption | Coil Type | Ingress Protection Rating | Installation | Preventive Maintenance Kit | Specifications Met |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 73212BN4TNLVN0C322C2 | 2 Way | Normally Closed | 1/2 | NPT | Internally Piloted | 5.0 | 300.0 | Brass | NBR | 185.0 | 77.0 | 1/2 | 2.80 | 24 VDC | 22.0 | 1/2" NPT Conduit w/ 18" Leads | NEMA 4,4X | IOM 7212 | 7K209 | CSA Listed Safety Shutoff Valve C22.2 no. 139-13 |
| 73218BN4UNLVN0C1113N | 2 Way | Normally Closed | 1/2 | NPT | Internally Piloted | 5.0 | 175.0 | Brass | NBR | 185.0 | 150.0 | 5/8 | 4.00 | 125 VDC | 10.0 | 1/2" NPT Conduit w/ 18" Leads | NEMA 4,4X | IOM 7212 | 7K815 | CSA Listed Safety Shutoff Valve C22.2 no. 139-13 |
| 73218BN4UNLVN0C111C2 | 2 Way | Normally Closed | 1/2 | NPT | Internally Piloted | 5.0 | 175.0 | Brass | NBR | 185.0 | 150.0 | 5/8 | 4.00 | 24 VDC | 10.0 | 1/2" NPT Conduit w/ 18" Leads | NEMA 4,4X | IOM 7212 | 7K815 | CSA Listed Safety Shutoff Valve C22.2 no. 139-13 |
| 73218BN4UNLVN0C111C4 | 2 Way | Normally Closed | 1/2 | NPT | Internally Piloted | 5.0 | 175.0 | Brass | NBR | 185.0 | 150.0 | 5/8 | 4.00 | 48 VDC | 10.0 | 1/2" NPT Conduit w/ 18" Leads | NEMA 4,4X | IOM 7212 | 7K815 | CSA Listed Safety Shutoff Valve C22.2 no. 139-13 |
| 73218BN4UNLVN0C111C6 | 2 Way | Normally Closed | 1/2 | NPT | Internally Piloted | 5.0 | 175.0 | Brass | NBR | 185.0 | 150.0 | 5/8 | 4.00 | 120 VDC | 10.0 | 1/2" NPT Conduit w/ 18" Leads | NEMA 4,4X | IOM 7212 | 7K815 | CSA Listed Safety Shutoff Valve C22.2 no. 139-13 |
| 73218BN4UNLVN0C111P3 | 2 Way | Normally Closed | 1/2 | NPT | Internally Piloted | 5.0 | 175.0 | Brass | NBR | 185.0 | 150.0 | 5/8 | 4.00 | 120/60, 110/50 | 10.0 | 1/2" NPT Conduit w/ 18" Leads | NEMA 4,4X | IOM 7212 | 7K815 | CSA Listed Safety Shutoff Valve C22.2 no. 139-13 |
| 73218BN4UNLVN0C111Q3 | 2 Way | Normally Closed | 1/2 | NPT | Internally Piloted | 5.0 | 175.0 | Brass | NBR | 185.0 | 150.0 | 5/8 | 4.00 | 240/60, 220/50 | 10.0 | 1/2" NPT Conduit w/ 18" Leads | NEMA 4,4X | IOM 7212 | 7K815 | CSA Listed Safety Shutoff Valve C22.2 no. 139-13 |
| 7321GBN99NLVN0C322C2 | 2 Way | Normally Closed | 2 | NPT | Internally Piloted | 5.0 | 175.0 | Brass | NBR | 185.0 | 77.0 | 1-9/16 | 38.6 | 24 VDC | 22.0 | 1/2" NPT Conduit w/ 18" Leads | NEMA 4,4X | IOM 7203 | 7KG10 | CSA Listed Safety Shutoff Valve C22.2 no. 139-13 |