The NG06 direct operated directional control valve D1VW with inductive position control provides high functional limits up to 80 l/min in combination with a low, energy saving pressure drop. It is typically used in safety relevant applications.

Especificações técnicas

  • Conexão da porta: NG06, CETOP 03
  • Tipo de montagem: Sub base, manifold
  • Tipo de atuação: Solenoid
  • Função: 2-way, 3-way
  • Pressão máxima de operação: P, A B: 350 ; T: 210 bar
  • Taxa de fluxo máximo: Depending on spool, max. 80 L/min
  • Temperatura máxima de operação: 60 °C
  • Temperatura mínima de operação: -20 °C
  • Para tipo de fluido: Hydraulic oil according to DIN 51524, Water glycol
  • Material de vedação: FPM, NBR
  • Peso: 1 solenoid: 1.8, 2 solenoids: 3.8 kg
  • Material do corpo: Cast iron
  • Temperatura máxima do ambiente: 60 °C
  • Temperatura mínima do ambiente: -25 °C
  • Configuração: Directional spool valve
  • Temperatura mínima do fluido: -20
  • Temperatura máxima do fluido: 70 °C
  • Viscosidade cinemática máxima: 400 cSt
  • Viscosidade cinemática mínima: 2.8 cSt
  • Classificação de eficiência de filtro: ISO 4406; 18/16/13

Descrição completa do produto

Parker’s direct operated directional control valve series D1VW with inductive position control in NG06 (CETOP 03 / NFPA D03) features low energy losses due to optimized flow passages. It offers high functional limits up to 80 l/min and a maximum pressure of 350 bar.

This on/off valve is typically used in safety relevant applications. It complies with the machinery directive 2006/42/EG for use as clamping valve according to EN 201:2010. The start or the end position can be monitored. The position control is available for single and double solenoid valves.

Markets:
• Industrial
• Molding

Features/Benefits:
• High functional limits – low forces resulting in safe operation also at high flow rates
• Low pressure drop – resulting in low energy losses in operation
• Wide product offering – many different options – all valves from one single source
• Short delivery time – no warehousing necessary

Applications:
• All types of safety relevant applications
• Injection molding (safety component according to machinery directive 2006/42/EG)

Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by Parker.

The fail-safe position of the directional valve during power failure is the spring offset or center position.